Register Plate or Closure Plate?





Untitled Document

A closure plate and a register plate are two different items used for the installation of stoves. A closure plate is used when you have a chimney liner (flexible) the closure plate closes the chimney to be cosmetic, this stops old soot dirt and moisture dropping on the stove and to stop heat disappearing up into the chimney. If the closure plate developed a fault, smoke could NOT enter the room. A closure plate can be made of any non-combustible material. A register plate is used when there is no chimney liner and acts as a barrier to the smoke and fumes in the chimney – it must make a sturdy seal between the room and the chimney and it MUST be made of galvanised or stainless steel (or other non-rusting metal) at least 2mm thick.

A register plate would usually have access doors to allow the sweep to access any chamber above it to remove fallen soot.

Why do closure plates need to be made of metal? That is because if a register plate failed then smoke could enter the room where the stove is burning. (e.g.) if a brick fell from inside of the chimney.

It is uncommon these days that liner are not fitted (although stove flue pipes might be connected directly to pot lined chimneys) and therefore register plates are less common on new installs. Modern wood burners are highly efficient and this means that LESS heat goes up the chimney. It is the heat that gives the draft (hot air rises and the hotter then the faster it rises).

The more efficient the wood burning stove the less heat is wasted up the chimney and the more likely that a liner, will be what the stove requires to function correctly.



What to Know When Installing Flue Liner – Chimfit





Untitled Document

Most of our customers here at chimfit fit their stove and or flue liner themselves. You do not have to use a professional installer if you are DIY savvy and have general competence, If you are installing the wood burning stove into an fireplace and not installing a new chimney liner then the installation is very straightforward. Installing a chimfit flexible chimney liner or complete twin wall flue system is a larger project and may involve ladders/scaffolding if your roof does not have external access, this is since it is needed for the job, is still is however technically straightforward. Our twin wall chimney system simply slots together, no specialist knowledge or skills are required.

If you are thinking of completing the work yourself then you should contact the local council Building Control, they can then inspect the work you have done and sign it off if it is up to standard. Alternatively if the work is done by a professional installer (Which we here at Chimfit recommend) who is accredited by one of the relevant Competent Persons schemes such as HETAS then they can sign off their work themselves.

chimfit

Old houses will usually have exposed brick inside the chimney so it is not a legal requirement to line these older chimneys with chimfits liner unless they are broken or leaking, there are often advantages to lining such as increased draw. Installation of a wood burning stove and/or new flue system would not usually have anything to do with the local planning authority. If your property is a Listed Building then permission may or may not be required. If you intend your new chimfit flue pipework to run up the outside of an external wall then depending on the position you may need to check with the local Planning Department.

twin wall flue pipe





Untitled Document

Installing a wood burner boiler stove or other heating appliance and planning to run your flue system through a wall or a floor, you will need to use a twin wall flue system.

Twin wall flues have a 1 inch of insulation around the inner layer pipe. The external diameter of twin wall pipe is two inches larger than the internal, which is the quoted diameter. This is due to the internal diameter being a crucial figure when drawing and designing a wood burner flue system, you should always keep in mind of this when installing, for instance if you were to be careless and purchase a 5 inch diameter twin wall pipe the external diameter will be 7 inches it could very well be too big for the install!

If you are passing through a wall you must always set it at the maximum angle of 45 degrees and also use a wall sleeve. You can finish the job off with finishing plates. If you are passing through an internal floor in your home you will need to use fire stop plates and remain at least 50mm away from combustible materials like joists.

Always have at least one length of single wall enamelled stove pipe as you cannot connect your twin wall pipe directly to your wood burner’s flue. It is then possible to use single wall pipe internally, we recommended that you do not go more than 1.5 meters before changing to twin wall but you certainly need to convert at least 4 inches before passing through a wall or floor. You should use an adaptor to single wall to allow you to convert to twin wall flue pipe and then once you have converted you must continue the flue system in twin wall.